Fire pump set Return on a page
Performance range:

1. Flow: 15-10000m3/hr

2. Head: 15-1800m

3. Caliber: DN65-DN350mm

4. Rotate speed: 750-2950 r/min

5. Water temperature: ≤80°C

6 .Motor power: 15-2800kw


Introduction:

Electric fire pump + Diesel fire pump +Jockey pump



Introduction:

Generally an automatic fire water supply system consists of a Jockey pump, an electric fire pump (main pump) and an automatic diesel fire pump set (standby pump).

The split type diesel engine control cabinet (programmble) can realize these functions: system's self-start, operation self-cut-over (from Electric pump to Diesel engine pump or from one diesel engine pump to another diesel engine pump), self-protection (in case of over speed of the diesel engine, low oil pressure, high water temperature, 3 times failure of start, low oil level and low voltage of the battery etc.). Besides, the pump can be connected with fire center or fire alarm, which can easily realize remote control.

The diesel fire pump group can be connected to electric constant pump to realize self fire water supply system.

With the difference in water inflow, the fire pump can be grouped into two groups: Self-filling pump, and suction pump. Normally we provide self-filling pump. If client needs suction system, please point out, our company will provide vacuum self suction device, with little changes of the pump size.

 

Performance and Characteristics:

Complete three starting functions:

1.Manual starting: available for manual and automatic interlocking and for manual starting through the change-over switch;

2.Automatic starting: allowable for three times of starting; sending out “starting failure alarm’ and exiting from the starting state in case of starting failure after three times; if starting is successful once, the time of starting to the rated load is 5-10-15S(subject to the pump set’s capacity);

3.Emergency direct manual starting: available for emergency direct manual starting in case of failure of the automatic control device.

4. Automatic operation: when the water pump set receives an effective fire control signal, the diesel fire pump set will start and operate automatically if the motor fire pump’s power supply system is power-off or open-phase or the electric pump fails to start normally. Once the power supply system returns to normal or the electric pump can work normally, it can be switched to the electric pump automatically.

5. Automatic stop: when the fire control signal disappears, the diesel fire pump will stop in a delayed and automatic way.

6. Automatic charge and voltage-stabilizing function of accumulator: the accumulator can use the mains supply for the automatic charge of the diesel’s rechargeable motor to ensure the pump set’s smooth starting.

 

Complete indicating system:

Ready to start, manual starting, automatic starting, set operation, set stop, accumulator charging, over speed, under pressure of diesel lubricating oil, under pressure of oil of pressure booster, under temperature of diesel lubricating oil, over temperature of diesel cooling water, under voltage of accumulator, too low level of fuel oil(or in short), preheating for under temperature of diesel cooling water, and timed in-process check.

 

Complete alarm or protection system:

Alarm or protection for starting failure for three times, over speed, under pressure of lubricating oil, under pressure of oil of pressure booster, over temperature of cooling water, and under temperature of lubricating oil; alarm for failure of automatic charging device and under voltage/over voltage of accumulator; and alarm or protection for low level of machine oil.

 

Complete display system:

1.Display of lubricating oil pressure and rotation speed of diesel, and charging current and voltage accumulator.

2. Adjustable flow and pressure: the diesel water pump is mounted with a mechanical or electronic speed regulator which can regulate and change the diesels rotation speed when the water pump's (low and lift head are not in conformity with the actual conditions.

3. Double accumulator loops: when one accumulator set fails, another set can be put into use automatically.

4. Maintenance-free accumulator: unnecessary for frequent filling of the make-up fluid.

5. Automatic timed in-process check test: generally the fire system is in a standby state, and this pump set is available for testing its standby state automatically and also for alarming promptly.

 

                                       

                                         

               A part of model see the table below 

Model

Flow

(m3/h)

Head

(m)

Power

(kw)

Speed

(r/min)

 

65D25-30x3

15

25

30

102

90

83

 

15

 

2950

 

65D25-30x4

15

25

30

136

120

110

 

18.5

 

2950

 

80D46-30x3

30

46

55

102

90

81

 

22

 

2950

 

80D46-30x6

30

46

55

204

180

162

 

37

 

2950

 

100D85-45x2

55

85

100

102

90

78

 

37

 

2950

 

100D85-45x5

55

85

100

255

225

195

 

90

 

2950

 

150D155-30x2

119

155

190

64

60

54

 

55

 

1480

 

150D155-30x3

119

155

190

96

90

81

 

75

 

1480

 

150D155-30x4

119

155

190

128

120

108

 

90

 

1480

 

150D155-67x3

100

155

185

228

201

177

 

132

 

2950

 

150D155-67x4

100

155

185

304

268

236

 

200

 

2950

 

 

 

全屏背景
脚注信息

Copyright © 2019 Tangshan Kylin Import & Export Co., Ltd. 海洋网络提供网站建设  BAIDU SITEMAP